Products Introduction

Content Introduction

The ProSoft MVI56E-DNPNET is an enhanced in-chassis DNP3 Ethernet communication module for Rockwell ControlLogix 1756 chassis. It supports DNP3 client and server functions simultaneously, enabling ControlLogix PAC to exchange real-time data, timestamps and event records with substation IEDs, RTUs, SCADA and DCS systems over Ethernet. It is widely used in power utility, oil & gas, water treatment and substation automation upgrade projects. It serves as a reliable spare replacement unit for DNP3 industrial network communication.

Product Details

This ProSoft MVI56E-DNPNET single-slot module installs directly into the ControlLogix backplane. It supports up to 40 DNP3 server devices as client, with 300 configurable commands and up to 20,000 data points. It can act as DNP3 server at the same time to respond to remote SCADA client requests. It supports timestamped event buffering, and cached events will be uploaded automatically once communication recovers.

It is equipped with one 10/100 Mbps Ethernet port and built-in web server for configuration, diagnostics and firmware upgrade. It adopts Add-On Instruction for RSLogix 5000 / Studio 5000, easy for tag mapping and commissioning. Front panel LED indicators display module status, backplane communication and Ethernet link status for fast on-site troubleshooting. Powered by the ControlLogix backplane, no separate 24V DC power supply is required. It is an ideal solution for integrating ControlLogix into DNP3 Ethernet substation networks.

Product Parameters


ParameterSpecification
ModelMVI56E-DNPNET
SeriesMVI56E ControlLogix In-Chassis Enhanced Communication Module
Continuous stall torque-
Continuous stall current-
Peak current-
Rated power4.5 W
Max speed10/100 Mbps Ethernet
Max voltageBackplane powered
Insulation class-
Protection classIP20
Feedback typeControlLogix 1756 backplane, DNP3 over Ethernet
Shaft-
MountingControlLogix 1756 chassis mounting
Ambient temperature range0°C to 60°C
Relative humidity5% to 95%, non-condensing
WeightRefer to manufacturer datasheet