Products Introduction

Content Introduction
The NI SCXI-1102C is an upgraded 32-channel differential multiplexer and amplifier module for thermocouple measurement in SCXI chassis. It features improved settling time compared to the original SCXI-1102, with built-in cold junction compensation and low-pass filtering to suppress power frequency noise. It is widely used for thermal cycling test, environmental temperature monitoring, aerospace and automotive thermal validation, and spare replacement of legacy SCXI temperature measurement systems.

Product Details
The SCXI-1102C is the revised version of SCXI-1102, with faster settling performance. It supports two selectable gain settings: 1 and 100. Each channel integrates a fixed 1 Hz low-pass filter to reduce 50/60 Hz interference for slow temperature signals.
The matching terminal block is SCXI-1303 for thermocouple wiring. It works with NI DAQ or PXI DAQ modules for data acquisition. This model is end-of-life and mainly supplied for refurbishment and replacement of existing SCXI test platforms.

Product Parameters
Channels: 32 differential analog input channels
Gain Options: 1, 100
Filter: Fixed 1 Hz low-pass filter per channel
CJC: Integrated cold junction compensation sensor
Input Range: ±10 V (gain=1), ±100 mV (gain=100)
Matching Terminal Block: SCXI-1303
Driver: NI-DAQmx
Form Factor: SCXI signal conditioning module
Operating Temperature: 0 ℃ to 55 ℃
Storage Temperature: -40 ℃ to 70 ℃
Operating Humidity: 10% to 90% non-condensing
Compatible Chassis: SCXI-1000, SCXI-1001

Tags: SCXI thermocouple module temperature multiplexer NI SCXI-1102C