2324139713@qq.com

NI PXI-5695 50 MHz to 8 GHz Two-Channel Programmable RF Attenuator PXI Module

NI PXI-5695 50 MHz to 8 GHz Two-Channel Programmable RF Attenuator PXI Module

NI PXI-5695 is an EOL PXI RF programmable attenuator with 70 dB max cascaded attenuation, 0.5 dB resolution and fast settling time for RF power control and dynamic range extension in automated ATE test systems.
Send Inquiry
Products Introduction

Content Introduction

The NI PXI-5695 is a single-slot 3U PXI programmable RF attenuator module for RF signal conditioning in modular PXI test systems. It features two independent attenuation paths, including one fixed attenuation channel and one software-programmable attenuation channel. When cascaded, the two paths deliver up to 70 dB total attenuation at 2.5 GHz for precise RF power level adjustment. It provides 0.5 dB fine attenuation resolution, fast settling time and calibrated amplitude accuracy, which greatly extends the dynamic range of vector signal generators and analyzers. It can replace traditional switched attenuator networks to control signal level for receiver sensitivity testing and RF component characterization. It supports synchronization with other PXI RF instruments via the PXI trigger bus and 10 MHz reference clock. Widely used for wireless communication test, radar RF signal conditioning, amplitude sweep measurement and aerospace automated ATE benches, this module is commonly stocked as spare replacement hardware.

Product Details

The NI PXI-5695 is a dual-channel RF attenuator designed for level control in PXI RF test platforms.
Channel 0 is a fixed attenuation path with more than 27.5 dB attenuation across the full frequency range.
Channel 1 is a programmable attenuator with up to 42 dB adjustable attenuation and 0.5 dB tuning resolution.
The two channels can be cascaded to achieve maximum total attenuation up to 70 dB at 2.5 GHz.
It offers fast attenuation settling time with maximum 4 μs switching speed for high-speed production test sequences.
Calibrated attenuation flatness and temperature compensation ensure consistent measurement accuracy across bandwidth.
Front-panel SMA connectors are used for RF input and RF output of each signal path.
It works with NI PXI vector signal generators and analyzers such as PXI-5671, PXI-5660 and PXI-5661.
It supports synchronized operation with RF synthesizers, switches and digitizers inside the same PXI chassis.
It runs under NI-5690 driver and supports programming via LabVIEW, LabWindows/CVI, C/C++, Python and IVI compliant software.
This is a discontinued end-of-life National Instruments PXI RF programmable attenuator module.
Typical applications include receiver sensitivity testing, RF power attenuation control, modulated signal level adjustment, amplitude sweep characterization and general RF component automated validation.

Product Parameters

Part Number: PXI-5695 (195809-01L)
Brand: National Instruments (NI)
Form Factor: 3U PXI, single slot
Frequency Range: 50 MHz to 8 GHz
Channels: 2 RF attenuation channels
Channel 0 Attenuation: >27.5 dB fixed attenuation
Channel 1 Attenuation Range: 0 dB to 42 dB programmable
Attenuation Resolution: 0.5 dB nominal
Max Cascaded Total Attenuation: 70 dB typical at 2.5 GHz
Attenuation Settling Time: 4 μs maximum
Calibration Accuracy: ±0.7 dB typical
Maximum Operating Input Power: +27 dBm
Maximum Reverse Power: +26 dBm
Input / Output Impedance: 50 Ω
Connector Interface: SMA female
Synchronization: PXI trigger bus, 10 MHz reference clock
Driver: NI-5690
Compatible Software: LabVIEW, LabWindows/CVI, C/C++, Python, .NET, IVI
Operating Temperature: 0 °C to 55 °C


Tags: NI PXI-5695 PXI-5695 RF attenuator 8GHz programmable attenuator PXI RF signal conditioning module