Products Introduction

Content Introduction
The NI PXI-2512 is a high-current PXI fault insertion switch module built for hardware-in-the-loop (HIL) and electronic reliability validation. It provides 7 feedthrough signal channels paired with two independent fault buses, supporting programmable fault simulation including open circuit, pin-to-pin short, short to battery voltage and short to ground. It features FET switching architecture, overcurrent detection and PXI trigger synchronization, ideal for automotive ECU, aerospace FADEC and industrial controller durability testing. It is widely stocked as spare hardware for high-current HIL test benches.

Product Details
The NI PXI-2512 is a single-slot 3U PXI fault insertion unit. Each of the 7 channels can be independently disconnected or routed to either of the two fault buses. It supports 10 A continuous carry current and up to 50 A pulsed current for 600 µs maximum, with 50 VDC / 30 V ACrms maximum switching voltage. Integrated overcurrent protection triggers at 10.5 A typical with 20 ms delay to protect the DUT and module. It supports PXI trigger bus for deterministic synchronized fault injection alongside simulation and DAQ tasks. This module uses two 8-pin D-Sub front connectors and works with NI dedicated shielded HIL cables. It runs under NI-SWITCH driver and works seamlessly with LabVIEW Real-Time and NI VeriStand real-time test platforms.
This is an end-of-life National Instruments FIU module. The PXIe-2512 is the corresponding PXI Express replacement variant.
Typical applications include automotive electronic HIL fault testing, aerospace control system validation, high-current signal fault simulation and legacy PXI-2512 fault insertion module spare replacement.

Product Parameters
Part Number: PXI-2512
Brand: National Instruments (NI)
Form Factor: 3U PXI, single slot
Channel Count: 7 feedthrough channels
Fault Bus: 2 independent fault buses
Switch Type: FET solid-state switch
Max Continuous Current: 10 A per channel
Max Pulsed Current: 50 A (max 600 µs)
Max Switching Voltage: 50 VDC, 30 V ACrms
DC Path Resistance: 16 mΩ typical, 35 mΩ maximum
Signal Bandwidth: 800 kHz
Protection Function: Overcurrent detection and fault protection
Synchronization: PXI trigger lines 0 to 7
Connector: 2 × 8-pin D-Sub male connectors
Driver: NI-SWITCH
Compatible Software: LabVIEW Real-Time, NI VeriStand, LabWindows/CVI, C/C++
Operating Temperature: 0 °C to 55 °C
Product Status: End of Life (EOL)
Typical Application: High-current HIL fault injection test, automotive ECU validation, aerospace electronic control reliability test
Tags: NI PXI-2512 PXI-2512 FIU module 7 channel 10A fault insertion unit PXI HIL switch