The NI PCI-4070 is a legacy PCI-bus high-performance FlexDMM for automated test systems. It combines precision multimeter functionality with an integrated isolated digitizer, supporting multi-function electrical measurement and high-speed waveform capture, widely stocked for component characterization, power transient testing and aerospace measurement applications.

Product Details
The NI PCI-4070 is a single-slot PCI digital multimeter known as FlexDMM. It delivers 6.5-digit resolution for standard DMM measurements and provides up to 1.8 MS/s sampling rate in isolated digitizer mode, far faster than conventional bench DMMs.
It supports DC voltage, AC voltage, DC current, AC current, 2-wire and 4-wire resistance measurement. The built-in isolated digitizer allows users to capture fast transient signals without requiring a separate oscilloscope module. Solid-state relays are used for range switching to reduce settling delay and improve test throughput.
Four banana jack terminals provide signal input. It supports synchronization with SCXI switching modules via trigger lines for multi-channel scanning test setups. It works with the IVI-compliant NI-DMM driver and integrates seamlessly with LabVIEW for automated test sequencing, leakage testing and dynamic electrical analysis.
This is an end-of-life National Instruments DMM. It is mainly supplied to maintain existing production and laboratory test benches. New high-speed precision measurement projects generally adopt newer PXIe DMM platforms.
Typical applications include semiconductor component testing, fuel cell measurement, power supply transient capture and legacy automated calibration station maintenance.
Product Parameters
Part Number: PCI-4070, 778275-01
Brand: National Instruments (NI)
Bus Interface: PCI 32-bit, 33 MHz
Resolution: 6.5-digit
Measurement Functions: DC Voltage, AC Voltage, DC Current, AC Current, Resistance
Max Voltage Range: ±300 V
Max Current Range: ±1 A
Resistance Modes: 2-wire, 4-wire remote sense
Digitizer Sample Rate: 1.8 MS/s
DC Voltage Basic Accuracy: 25 ppm
Connectors: Banana jack terminals
Protection: Overvoltage protection on all input ranges
Synchronization: SCXI trigger bus supported
Supported Driver: NI-DMM (IVI compliant)
Compatible Software: LabVIEW, LabWindows/CVI
Product Status: End of Life (EOL)
Typical Application: Precision electrical characterization, fast transient signal capture, legacy PCI DMM spare replacement