NI cFP-RTD-122 RTD Input Module

NI cFP-RTD-122 RTD Input Module

NI cFP-RTD-122 is a 16-bit 8-channel 2/3-wire RTD module for Compact FieldPoint, for Pt100 and Pt1000 industrial temperature measurement.
Send Inquiry
Products Introduction

Product Brief

The NI cFP-RTD-122 is an 8-channel RTD and resistance input module for Compact FieldPoint systems. It supports 2-wire and 3-wire Pt100 / Pt1000 sensors for temperature measurement, widely used as spare parts for legacy industrial temperature monitoring systems.

Product Details

The NI cFP-RTD-122 mounts on Compact FieldPoint backplanes and provides eight channels for RTD and resistance measurement. It works with 2-wire and 3-wire RTD probes, and the 3-wire mode compensates most lead resistance error for better temperature accuracy.

This module uses 0.25 mA excitation current and 16-bit delta-sigma ADC. Users can read values as temperature in °C, °F, °K or raw resistance ohms via software. Built-in 50/60 Hz filtering suppresses power line noise in factory environments. The full scan time for all 8 channels is 1.08 seconds.

It has bank isolation rated at 2300 Vrms for transient surge protection. It supports hot swap and auto-configuration, so replacement can be done without shutting down the entire backplane bank. Measurement data and channel setup are accessible through LabVIEW, NI MAX and FieldPoint OPC Server.

This is an end-of-life legacy NI module. It only operates within Compact FieldPoint architecture with compatible drivers. It is mainly stocked for maintaining existing temperature monitoring nodes. New projects usually choose CompactRIO C-series RTD modules.

Rugged industrial construction is designed for DIN rail cabinet installation. Typical uses include furnace, pipeline and machine temperature monitoring with Pt100 and Pt1000 sensors.

Product Parameters

Part Number: cFP-RTD-122

Brand: National Instruments (NI)

Channel Count: 8 RTD / resistance input channels

Resolution: 16-bit, delta-sigma ADC

Supported Sensor: 2-wire, 3-wire Pt100, Pt1000

Excitation Current: 0.25 mA

Resistance Ranges: 0 – 400 Ω, 0 – 4000 Ω

Scan Time (All Channels): 1.08 s

Isolation Rating: 2300 Vrms bank isolation

Filter: 50 Hz / 60 Hz noise rejection

Feature: Hot swappable, auto-configuration

Mounting: Install on Compact FieldPoint backplane

Compatible Platform: All Compact FieldPoint backplanes and controllers

Supported Software: LabVIEW, NI MAX, FieldPoint OPC Server

Product Status: End of Life (EOL)

Typical Application: Pt100 temperature acquisition, industrial RTD measurement, legacy FieldPoint spare replacement


Tags: NI cFP-RTD-122 cFP-RTD-122 module Compact FieldPoint RTD input NI 8 channel RTD module

Reliance Electric 57407 AutoMa